Thursday, October 29, 2015

3G_RRU3808 Description V1.2


The RRU3808 performs modulation, demodulation, data processing, and combination and division of baseband signals and RF signals.

1.1 Appearance

Figure 1-1 shows an RRU3808.



1.2 Physical Ports


Table 1-1 Physical ports on the RRU3808
Port
Connector
Quantity
Function
Power supply port
OT terminal
1
–48 V DC power supply port
Optical port
DLC connector
2
Transport ports
Communication port for the RET antenna
DB9 connector
1
Other ports
Main TX and RX port
DIN waterproof female connector
1
RF ports
Diversity RX port
DIN waterproof female connector
1
Commissioning port
RJ45 connector
1
Other ports



2.1 Frequency Band

Table 2-1 RRU3808 frequency band
Frequency Band
RX Frequency Band (MHz)
2100 MHz
1920 to 1980
2110 to 2170
AWS
1710 to 1755
2110 to 2155

2.2 Capacity

One RRU3808 supports four carriers.

2.3 Receiver Sensitivity

Table 2-2 RRU3808 receiver sensitivity
Frequency Band
1-Way Receiver Sensitivity (dBm)
2-Way Receiver Sensitivity (dBm)
4-Way Receiver Sensitivity (dBm)
2100 MHz/AWS
–125.8
128.6
–131.3
note
As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.

2.4 Output Power

One RRU3808 supports four carriers with 2*40 W output power at the antenna connector of the RF module.
The RRU3808 supports one TX channel, MIMO, and combination of one TX channel and MIMO.
l   One TX channel: maximum output power of a TX channel reaching 40 W
l   MIMO: maximum output power reaching 40 W + 40 W
l   Combination of one TX channel and MIMO: maximum output power of a TX channel reaching 40 W


note
Maximum output power = Maximum output power of the PA - Internal losses. The maximum output power is measured at the antenna connector of the RF module.

2.5 Power Consumption

note
l  The typical power consumption is the DBS3900 works with a 40% load at 25°C ambient temperature.
l  The maximum power consumption is the DBS3900 works with a 100% load at 25°C ambient temperature.

Table 2-3 DBS3900 non-MIMO (RRU3808, 2100MHz) power consumption
Configuration
Output Power per Carrier (W)
Typical Power Consumption (W)
Maximum Power Consumption (W)
Power backup duration based on new batteries and typical power consumption (hour)
50Ah
92Ah
3 x 1
20
410
490
5.2
10.7
3 x 2
20
510
640
4.0
8.5
3 x 3
20
740
950
2.6
5.5
3 x 4
20
800
1060
2.4
4.9
note
l In the 3x1 or 3x2 configuration, one WBBPb4 and one WMPT are configured.
l In the 3x3 or 3x4 configuration, two WBBPb4 units and one WMPT are configured.

Table 2-4 DBS3900 MIMO (RRU3808, 2100MHz) power consumption
Configuration
Output Power per Carrier (W)
Typical Power Consumption (W)
Maximum Power Consumption (W)
Power backup duration based on new batteries and typical power consumption (hour)
50Ah
92Ah
3 x 1
10 + 10
460
570
4.5
9.4
3 x 2
10 + 10
580
730
3.6
7.2
3 x 3
10 + 10
730
950
2.6
5.6
3 x 4
10 + 10
800
1060
2.4
4.9
note
l In the 3x1 configuration, one WBBPb4 and one WMPT are configured.
l In the 3x2 configuration, two WBBPb4 units and one WMPT are configured.
l In the 3x3 configuration, three WBBPb4 units and one WMPT are configured.
l In the 3x4 configuration, four WBBPb4 units and one WMPT are configured.

Table 2-5 DBS3900 non-MIMO (RRU3808, AWS) power consumption
Configuration
Output Power per Carrier (W)
Typical Power Consumption (W)
Maximum Power Consumption (W)
Power backup duration based on new batteries and typical power consumption (hour)
50Ah
92Ah
3 x 1
20
410
482
5.2
10.8
3 x 2
20
518
632
4.0
8.4
3 x 3
20
721
931
2.7
5.6
3 x 4
20
835
1051
2.3
4.7
note
l In the 3x1 or 3x2 configuration, one WBBPb4 and one WMPT are configured.
l In the 3x3 or 3x4 configuration, two WBBPb4 units and one WMPT are configured.

Table 2-6 DBS3900 MIMO (RRU3808, AWS) power consumption
Configuration
Output Power per Carrier (W)
Typical Power Consumption (W)
Maximum Power Consumption (W)
Power backup duration based on new batteries and typical power consumption (hour)
50Ah
92Ah
3 x 1
10 + 10
470
572
4.4
9.2
3 x 2
10 + 10
628
766
3.2
6.7
3 x 3
10 + 10
774
975
2.5
5.1
3 x 4
10 + 10
890
1109
2.1
4.3
note
l In the 3x1 configuration, one WBBPb4 and one WMPT are configured.
l In the 3x2 configuration, two WBBPb4 units and one WMPT are configured.
l In the 3x3 configuration, three WBBPb4 units and one WMPT are configured.
l In the 3x4 configuration, four WBBPb4 units and one WMPT are configured.

2.6 Input Power

Table 2-7 Input power
Item
Specification
Input power
–48 V DC; voltage range: –36 V DC to –57 V DC


2.7 Equipment Specifications

Table 2-8 Equipment specifications
Item
Specification
Dimensions (H x W x D)
480 mm x 270 mm x 140 mm (without the connectors and housing)
485 mm x 285 mm x 170 mm (with the housing)
Weight
17 kg (without the housing)
19 kg (with the housing)

2.8 Environment Specifications

Table 2-9 Environment specifications
Item
Specification
Operating temperature
RRU3808
–40 to +55 (without solar radiation)
–40 to +50 (with solar radiation)
Relative humidity
5% RH to 100% RH
Absolute humidity
1–30 g/m3
Atmospheric pressure
70 kPa to 106 kPa
Operating environment
Compliance standards:
3G TS25.141 V3.0.0
ETSI EN 300019-1-4 V2.1.2 (2003-04) Class 4.1: "Non-weather protected locations"
Shockproof protection
NEBS GR63 zone4
Ingress Protection (IP) rating
IP65





Table 3-1 Acronyms and abbreviations
Acronym and Abbreviation
Full Name
BBU
Baseband control Unit
BER
Bit Error Ratio
RRU
Radio Remote Unit
WBBP
WCDMA Baseband Process unit
WMPT
WCDMA Main Processing and Transmission unit